APPLICATIONS •Emission Analysis •Process Gas Monitoring and Control •Environmental Gas Analysis •Combustion Products Analysis •Stack Gas Analysis •Laboratories •Tunnels DESCRIPTION The Series 6000i is manufactured to exacting specifications using state-of-the-art technology. Component quality is maintained by rigorous process and quality control standards. The software engine performs calculation and compensation procedures to ensure reliability with highly repeatable performance. The embedded temperaturecontrol, advanced signal-processing, and optional pressure compensation algorithms allow the AGM 6000i system developers to achieve performance levels specified in more expensive, high-end gas analyzers. Various standard sensor elements are available to adapt the Advanced Gasmitter® to specific customer requirements. Enhanced flexibility makes the Advanced Gasmitter® an ideal choice for variety of gas measurement of single gas components or specific gas mixtures from 0-100% and 02000ppm by volume with high resolution and low signal-to-noise ratio. Total design flexibility is possible by choosing different IR sources or TC detectors, sample cells, or detector combinations to optimize form, fit, and function. The modular design allows the product to be optimized for specific customer requirements
规格说明
Measuring Principle: Non Dispersive Infrared (NDIR) Dual Wavelength, Single Beam. No moving parts and Thermal Conductivity, (TC), detection or Electrochemical,UV Fluorescence, (ECC/Fuel Cell), principle, Diode Laser ,GC-PID,PID Gases and Ranges: CO/CO2/NO/NO2/N2O/HCl/SO2/SF6/H2S/NH3: 0-100/500/2000/5000ppm (NDIR) CO/CO2/ CH4 /NO/NO2/N2O/HCl/SO2/H2S : 0-1/2.5/5/10/20/35/50/100% (NDIR) H2/He/Xe : 0-10/20/50/80/100 % (TCD) VOC : 1ppb-20ppm / 0-100ppm / 0-500ppm / 0-1000ppm ,Other range O3 :0-50, 500, 200 ppb, 20 ppm,100 ppm. Other available. (UV) NH3:0-100ppm/0-1000ppm/0-1% (Laser) ,Other ranges on request Repeatability: ± 0.2% at Zero, ± 1% at Span Lower Detection Limit: < 1% FS Linearity Error: < 2% FS Temperature Range: 0°C to +50°C Storage Temp.: -20°C to +60°C Temperature Dependence: ± 1% FS/10° Kelvin at Zero, ± 2% FS/10° Kelvin at Span Temperature Controlled Heater: 55°C ± 5°C (optional) Pressure Dependence: 0% at Zero, < 2% FS/10mbar at Span (non compensated) Pressure Compensation: <0.2% FS/10mbar at Span Humidity Range: 0 - 95%RH non condensing Enclosure (option): Weather Proof & Explosion Proof For Class I, Division 1, Groups A, B, C, & D Input & Output Signal: 4-20mA, Linearized, Modbus RS232, Alarm Fault Relay Contacts